SHUGGIE | 13:24 Sun 14th Jan 2007 | DIY
4 Answers
i have moved my fuel tank and have now got an air lock in the system. i can get fuel to my tigerloop but not to the boiler.how do i bleed the bolier.it is a worcester boiler
thanks
shuggie
Gravatar

Answers

1 to 4 of 4rss feed

Best Answer

No best answer has yet been selected by SHUGGIE. Once a best answer has been selected, it will be shown here.

For more on marking an answer as the "Best Answer", please visit our FAQ.
I think you have had no response here because we cannot answer without knowing what kind of tank , fuel , position, pipe work , sizes distances ect...and other things you expect us to know ??????????
Question Author
hi gas man
the fuel is kerosene the tank is 1250l pipe size is 10mm and distance is no more than 10m but all this is irrespective as i have fuel to the tiger loop at the back door.
i was wondering how to bleed the boiler pump. sory for the confusion thanks
suggie
The pipe size sounds fine to me to cope with the viscosity of Kerosene. You say you have fuel to the tiger loop so i presume you mean that it is primed. You now need to bleed the burner on the boiler. Is it a Single pipe system ? If so then Release the fuel bleed port on the manifold and place a suitable container beneath. Turn on the Central Heating Control Thermostat. Set the operating switch (or programmer) to heating and hot water and allow the burner to run through to Lockout. Wait two minutes and reset the burner control box. Repeat the procedure at least three times or until a steady stream of fuel, without air, is exhausted from the bleed port. Relock the bleed port.
Question Author
hi gas man
thanks for the help much appreciated. I will let you know how i get on
thanks agian shuggie