Hi, Thanks for recomendation buidersmate, will try to help. it may be possible for you to fit what is called an "RCBO" which is in effect an rcd that replaces an MCB in your consumer unit, all you have to do is remove MCB controlling sockets with the rcbo, the lives and neutral attach to it and small wire goes to earth terminal ask local sparky to check if it is possible to get one to fit the unit you have,
Or you could have an RCD fitted between meter and unit this would give RCD protection on whole installation, the down side to this is, it may trip if lamp goes or you get slight fault on cooker ring etc, you then lose all power, so I would not go for that. but it is cheap way to give RCD protection. only trouble is if you want consumer unit changed is, the earthing might not be up to current standards which would bump up the cost of work, lso then it would need complete check on installation. good luck, Ray