How does a room thermostat work in conjunction with the radiator thermostat ?
Answers
No best answer has yet been selected by Bazile. Once a best answer has been selected, it will be shown here.
For more on marking an answer as the "Best Answer", please visit our FAQ.radiator therm dicatate how hot the radiator gets - I set mine low
Room therm senses the room temp and tells the boiler to go on or not
and yes it is poss to set your radiators so low ( which I do intentionally) so that the boiler is hardly ever heating
I also have a gas fire - heating is a way of life ( open flame etc, very victorian) and not just " is it warm enough"
Quite simply, it doesn't.
The room thermostat will turn the boiler on or off in accordance with the temperature it is set to do so. If you have a TRV (Thermostatic Radiator Valve) in the same room the only time it will have any effect is if it is set to a lower temperature than the room thermostat. It will then turn the rad off before the room thermostat shuts the boiler down. If it is set higher, the boiler will be shut off before it reaches that temperature.
The two work independently.
"So if you want one room to be at 10° and another to be at 15° and the room thermostat is in the room for the 10° then the other room will not reach 15° ?"
Correct.
I installed my central heating system (apart from connecting the boiler to the gas supply). I fitted TRVs on every rad and never had a room thermostat. When I had a new boiler installed few years ago I was told a room 'stat was mandatory under the regs. (Climate Change, don'tcha know). So I simply set it to its maximum on day one and haven't touched it since.
Canary - not necessarily. If the room set to 10 has a very small radiator and the window left open and the room set to 15 has a very large radiator and all windows closed the 15 room will heat up more quickly and can reach 15 before the other room reaches 10. When the 15 room reaches 15 the TRV will shut off the radiator but the 10 room will continue to heat until the room stat turns the whole system off at 10 deg in that room.
nicebloke - it's also common practice for the non-TRV radiator to be in the bathroom. If the room stat is set very high the pump will continue to run pumping water to all the radiators. If all rads have a TRV and they all close the pump will be running and pushing against a closed system - not good. By leaving one radiator always open without a TRV there is always a release for the pumped water. This also a reason the bathroom is often chosen for that radiator.
"In practice there should be one radiator without a TRV, the room stat should be near or in the same room. Mine is in the hallway the coldest part of the house in winter."
Nothing wrong with that. It's unnecessary, though. and simply introduces a complication to the control over your heating . There's no reason why you should not have a TRV on every rad.
"If all rads have a TRV and they all close the pump will be running and pushing against a closed system - not good."
That's why closed systems should either have a bypass fitted or (more common these days) have one incorporated in the boiler itself.