Donate SIGN UP

16 bit window substream

Avatar Image
peanut42 | 23:42 Mon 13th Dec 2004 | Technology
4 Answers
Since i've installed sp2 i get the command 16 bit window substream,and a lot of rubbish saying that the system file is not suitable for running MSDOS and microsoft windows applications
I would be grateful if somebody would help me with what this means and how i can get round it.................f
Gravatar

Answers

1 to 4 of 4rss feed

Best Answer

No best answer has yet been selected by peanut42 . Once a best answer has been selected, it will be shown here.

For more on marking an answer as the "Best Answer", please visit our FAQ.

CAUSE
This issue may occur if one or more of the following files are missing or damaged: Config.nt ,Autoexec.nt or Command.com

1. Insert the CD into drive.
2. Click Start,then click Run.
3. In the Open box, type cmd, and then click OK.
4. At the command prompt, type the following commands, pressing ENTER after each command:

expand CD-ROM Drive Letter:\i386\config.nt_ c:\windows\system32\config.nt
expand CD-ROM Drive Letter:\i386\autoexec.nt_ c:\windows\system32\autoexec.nt
expand CD-ROM Drive Letter:\i386\command.co_ c:\windows\system32\command.com
exit 

5. Start or install the program. If the issue is resolved, do not complete the remaining steps. If the issue is not resolved, go to the next step.
6. Note: The Command.com file is not edited or created in this in the following process. Because of this, you may have to expand it from your Windows XP CD-ROM.

Start Notepad.
7. In Notepad, type the following entries:    dos=high, umb
device=%SYSTEMROOT%\system32\himem.sys
files=40
 
8. On the File menu, click Save As.
9. In the File Name box, type Config.nt, and then click Save. Close the Config.nt file.
10. On the File menu, click New.
11. In the new blank document, type the following entries: @echo off
    lh %SYSTEMROOT%\system32\mscdexnt.exe
    lh %SYSTEMROOT%\system32\redir
    lh %SYSTEMROOT%\system32\dosx
    SET BLASTER=A220 I5 D1 P330 T3
 
12. On the File menu, click Save As.
13. In the File Name box, type Autoexec.nt, and then click Save. Close the Autoexec.nt file.
14. Start Windows Explorer. Locate the Config.nt file, right-click the Config.nt file, and then click Copy.
15. Right-click the %SYSTEMROOT%\System32 folder, and then click Paste.
16. Locate the Autoexec.nt file, right-click the Autoexec.nt file, and then click Copy.
17. Right-click the %SYSTEMROOT%\System32 folder, and then click Paste.
18. Locate the Command.com file, right-click the expanded Command.com file, and then click Copy.
19. Right-click the %SYSTEMROOT%\System32 folder, and then click Paste. Restart your computer.
If the issue continues to occur, copy the Autoexec.nt and Config.nt files from the Repair folder in Windows to the System folder. To do so, follow these steps:

1. Click Start, click Run, type c:\windows\repair, and then click OK.

2. Right-click autoexec.nt, and then click Copy. 

3. Click Start, click Run, type c:\windows\system32, and then click OK.

4. Right-click anywhere in that folder, and then click Paste.

5. Right-click the Autoexect.nt file that you just copied, and then click Properties.

6. Click to select Read-Only, and then click OK. 

7. Repeat steps 1 through 6 to copy the Config.nt file.

Note You must enable Read-Only permissions or the files will be removed after you restart Windows.

1 to 4 of 4rss feed

Do you know the answer?

16 bit window substream

Answer Question >>

Related Questions

Sorry, we can't find any related questions. Try using the search bar at the top of the page to search for some keywords, or choose a topic and submit your own question.