central heating
2 Answers
could someone possibly tell me why my heating is playing up
ive had new pump fitted by heating engineer but the problem is still there again 2 months later
the heating upstairs is fine but not downstairs
it is all on the same system ive had prob for ages now nobody knows the prob
thanks
ive had new pump fitted by heating engineer but the problem is still there again 2 months later
the heating upstairs is fine but not downstairs
it is all on the same system ive had prob for ages now nobody knows the prob
thanks
Answers
Best Answer
No best answer has yet been selected by johnant. Once a best answer has been selected, it will be shown here.
For more on marking an answer as the "Best Answer", please visit our FAQ.It could be that the radiators valves upstairs are wide open this will offer no resistance to the water flow so it will go the easiest way. You will need to shut down each radiator at one end (The opposite end to the radiator thermostat if fitted) this end will probably have a cap on rather than a knob take this off then open the valve slightly. You will probably need to open the ones farthest from the pump a little more.
This should then build up the pressure and the water should then go downstairs. Follow the same steps downstairs.
Hope this helps
Trackman
This should then build up the pressure and the water should then go downstairs. Follow the same steps downstairs.
Hope this helps
Trackman
They probabley need balancing try this and they should work. if it does not work then let me know.
Click on this link for instructions on how to balance a system. Good Luck.
http://www.theanswerbank.co.uk/Home-and-Garden /Question317227.html
Click on this link for instructions on how to balance a system. Good Luck.
http://www.theanswerbank.co.uk/Home-and-Garden /Question317227.html