Hot Water To Bath Running Cold
The hot water to my bath is running cold. I have a combi boiler with no other hot water problems. It used to be absolutely fine. When I run the hot water, it runs luke warm, if I run the hot water to the basin after I try the bath tap, it's really hot, as if the hot water has backed up into the basin tap. Someone mentioned the diverter valve in the boiler but I just don't know. Plumbers seem to think there's nothing wrong with the pipe work. Any suggestions?
Answers
What kind of bath taps do you have jmck?
12:28 Sun 23rd Jun 2013
-- answer removed --
Sorry I've only just picked up your reply jmck.
I was wondering if it was mixer taps. A problem with a diverter valve will affect ALL hot outlets. Quite logical if you think about it. It's all 15mm pipework with a combi, so I'd rule out any flow problems.
I would say the mixer tap is faulty, allowing cold water to cross over to the hot side. Perhaps it's a "cartridge" type. The cartridge could need replacing. Either that, or treat yourself to some new taps.
I was wondering if it was mixer taps. A problem with a diverter valve will affect ALL hot outlets. Quite logical if you think about it. It's all 15mm pipework with a combi, so I'd rule out any flow problems.